Commercial and Industrial Uses of Hygrometers

Commercial and Industrial Uses of Hygrometers

User avatar placeholder
Written by hygrom5987

13/04/2020

An industrial hygrometer is a humidity instrument built for a process rather than a room. What separates it from a household unit is not a better sensor so much as three other things: a measuring range that covers the conditions actually present, an output a control system can read rather than only a display, and a calibration that can be traced back to a national standard. Many industrial instruments report dew point instead of relative humidity, because moisture content — not comfort — is what damages a pipeline, a coating or a batch of plastic pellets.

Industrial and Commercial Uses of Hygrometers

Industrial uses of hygrometers include meteorological monitoring, automating manufacturing processes in photographic film, pharmaceuticals and steel production, monitoring environments in museums, storage vaults and clean rooms, environmental testing, product research and measuring water vapor in plant air, automotive exhaust and curing ovens. Small, portable devices, wall units, decorative brass hygrometers and freestanding equipment provide accurate readings in production rooms, server rooms, secure storage areas, greenhouses and indoor and outdoor sports training areas. Wall hygrometers, or combined thermohygrometers, provide temperature and humidity readings and can be used efficiently in plant nurseries, greenhouses, offices and food-storage areas. Some specific uses for hygrometers in industry include the following applications:

Process Applications, Sector by Sector

  • Polyethylene production
    Excess moisture in polyethylene production decreases yields, so checking ethylene feed lines for moisture is critical for maximum production.
  • Hydrogen-cooled generators
    Moisture is considered a contaminant that increases hydrogen viscosity and decreases heat capacity in stationary generators.
  • Liquefaction of natural gas
    Trace amounts of water can compromise the process of gas liquefaction by generating hydrates and ice that damage compressors.
  • Breathing applications
    The military, fire departments and medical community need to ensure that breathing apparatuses are safe and that moisture doesn’t form ice to block breathing lines.
  • Food packaging
    Foods that are warped in foil have longer shelf lives when the air that is trapped between food and foil is replaced with low-moisture nitrogen.
  • Compressor system instrumentation
    Humidity in gases used for blanketing sensitive instruments causes corrosion, faster changes in instruments needing calibration and degraded sensitivity.
  • Natural gas lines
    Moisture in gas lines can cause pipelines and valves to freeze or contaminate the system with hydrates of liquid hydrocarbons.
  • Injection molding
    Testing for humidity in the air that is used to dry plastic pellets helps to prevent blemishes, cloudy appearances and weakened structural integrity.
  • Coatings industry
    Coatings used in construction are sensitive to the dew point and humidity. Incorrect climate during treatment can lead to premature failure of coatings and paint and cause blemishes in surfaces.
  • Incubators
    Temperature and humidity are critical to improve hatch rates. Get best results by keeping humidity between 50 and 55 percent until the last three days when ambient moisture should measure between 65 and 70 percent.

What Makes a Hygrometer “Industrial”?

The gap between a shelf hygrometer and a process instrument is mostly about proof and survival, not about the sensing element. A good consumer sensor is already better than most people need: Sensirion’s widely used SHT4x parts are specified at ±1.8% RH typical, with long-term drift under 0.2% RH per year. What a plant needs on top of that is evidence the reading is right, at the condition that matters, in an environment that would destroy a bookshelf unit.

RequirementHousehold hygrometerIndustrial instrument
What it reportsRelative humidity, plus temperatureOften dew point or moisture content, because that is what the process reacts to
Where the reading goesA display someone glances atA control system, a data logger or an alarm, continuously
How accuracy is establishedA salt test at one point, roughly 75% RHCalibration traceable to a national standard, at the points the process uses
Operating conditionsA heated room, roughly 30–50% RHPressure, heat, dust, solvents, or very dry gas — sometimes all at once
Cost of being wrongMild discomfort, or mould if ignored for monthsA scrapped batch, a frozen valve, a failed coating or a damaged compressor

That last row is the real dividing line. Household monitoring is forgiving because the comfortable band is twenty points wide. A process tolerance is usually a few points wide and often sits at the dry or wet extreme, exactly where inexpensive sensors are least reliable — the same reason a humidor gauge has to be calibrated while a living-room unit does not.

Dew Point or Relative Humidity?

Relative humidity compares the water vapour in the air with the most that air could hold at its current temperature. That makes it useful for comfort and for mould risk, and awkward for a process, because the number moves when the temperature moves even though nothing has been added to or removed from the gas.

Dew point is the temperature at which the gas would begin to condense. It describes the moisture itself, and it does not shift when the gas is heated or cooled. For compressed air, natural gas lines, drying ovens and blanketing gases, the moisture content is the thing that causes the damage, so dew point is the number worth controlling. This is why the laboratory reference instruments in this field are chilled-mirror hygrometers, which determine dew point directly by detecting condensation on a cooled surface, and why national calibration services are built around dew-point instruments as well as relative-humidity ones. The underlying measurement principles are covered in our explainer on how hygrometers work and in the terminology guide.

Calibration and Traceability

In a plant, an uncalibrated instrument is not a measurement — it is an opinion. Comparing two working hygrometers against each other establishes only that they disagree, which is why industrial practice works down a chain from a national standard rather than sideways between instruments.

NIST sits at the top of that chain in the United States, calibrating dew-point and mole-fraction hygrometers and thermohygrometers to an expanded relative uncertainty below 0.3% for relative humidity. Below that, working instruments are checked against a calibrated transfer standard, or against fixed points whose values are published reference data: a saturated sodium chloride solution holds the air above it at 75.47% ±0.14 at 20 °C and 75.29% ±0.12 at 25 °C, figures established by Greenspan’s 1977 study for the US National Bureau of Standards. The domestic version of that same method is the salt test; the industrial version differs in that the result is documented, repeated on a schedule, and carried out at more than one point. How far any instrument can be trusted between calibrations is the subject of our guide to hygrometer accuracy.

What is an industrial hygrometer?

An industrial hygrometer is a humidity instrument built for a process rather than a room. In practice that means three things a consumer unit does not offer: a measuring range that covers the conditions actually present, an output the control system can read rather than only a display, and a calibration that can be traced back to a national standard. Many industrial instruments report dew point rather than relative humidity, because that is what the process cares about.

What is the difference between an industrial and a household hygrometer?

Purpose and provability. A household hygrometer has to be roughly right across a twenty-point comfort band, and you verify it with a salt test. An industrial instrument has to be demonstrably right at a stated uncertainty, often at the dry or wet extreme where consumer sensors are weakest, and it has to survive the temperature, pressure, dust or chemistry of the process around it.

Why do industrial processes measure dew point instead of relative humidity?

Because relative humidity changes when the temperature changes even though the amount of water in the gas has not. Dew point, the temperature at which the gas would begin to condense, describes the moisture content itself. For a compressed air line, a natural gas pipeline or a drying oven, the moisture content is the thing that causes damage, so dew point is the more useful number.

How are industrial hygrometers calibrated?

Against a reference, not against another working instrument. National metrology institutes provide the top of that chain: NIST calibrates dew-point and mole-fraction hygrometers and thermohygrometers to an expanded relative uncertainty below 0.3% for relative humidity. Working instruments are then checked against a calibrated transfer standard or against fixed points such as saturated salt solutions, whose humidity values are published reference data.

What humidity level do industrial and storage environments need?

There is no single figure, because the target follows the material rather than human comfort. A cigar store, a museum store, a clean room, a seed store and a compressed air line all have different requirements, and several of them sit well outside the 30 to 50% band that suits a house. The working rule is that the narrower the tolerance and the further it sits from the middle of the scale, the more instrument and calibration the job needs.